1. 如何解決脈沖輸出時(shí)伺服電機(jī)不運(yùn)轉(zhuǎn)的問(wèn)題?
-監(jiān)視控制器的當(dāng)前脈沖輸出值,并檢查脈沖輸出指示燈是否閃爍以確認(rèn)控制器執(zhí)行了命令脈沖并正常輸出脈沖;
-檢查控制器和驅(qū)動(dòng)器之間的控制電纜,電源電纜,編碼器電纜是否匹配錯(cuò)誤或接觸不良;
-檢查裝有制動(dòng)器的伺服電機(jī)的制動(dòng)器是否已打開(kāi);
-監(jiān)視伺服驅(qū)動(dòng)器的面板,確認(rèn)是否輸入脈沖命令;
-運(yùn)行命令是否正常;
-對(duì)于控制模式,始終選擇位置控制模式;
-檢查伺服驅(qū)動(dòng)器設(shè)定的輸入脈沖類型是否與指令脈沖的輸入脈沖類型一致;
-確保正轉(zhuǎn)側(cè)驅(qū)動(dòng)禁止,負(fù)轉(zhuǎn)側(cè)驅(qū)動(dòng)禁止信號(hào)和偏差計(jì)數(shù)器復(fù)位;
-信號(hào)未輸入,如果卸載負(fù)載,伺服電機(jī)正常運(yùn)行,則檢查機(jī)械系統(tǒng)。
1. Servo motor does not run when the pulse is output, how to solve the problem?
-Monitor the current pulse output value of controller and check if pulse output indicator lamp flashes to confirm that the controller has performed command pulse and has output pulse normally.
-Check if the control cable, power cable, encoder cable between controller and driver are matched incorrectly damaged or contacted poorly.
-Check if the brake of servo motor equipped with brake has been turned on.
-Monitor the panel of servo driver to confirm if the pulse command has been input.
-Run command is normal.
-For control mode, always choose position control mode.
-Check if the type of input pulse set by servo driver matches with that of command pulse.
-Ensure that positive side drive prohibition, negative side drive prohibition signals and deviation counter reset signal are not input and the servo motor runs normally if load is removed, then check the mechanical system.
GLENTEK伺服電機(jī)GM4040-41-02003700
2.如何解決伺服電機(jī)高速旋轉(zhuǎn)時(shí)出現(xiàn)電機(jī)偏差計(jì)數(shù)器溢出錯(cuò)誤的問(wèn)題?
當(dāng)伺服電機(jī)高速旋轉(zhuǎn)時(shí),電機(jī)偏差計(jì)數(shù)器出現(xiàn)溢出錯(cuò)誤。
失效分析:檢查電機(jī)電源電纜和編碼器電纜的配線是否正確以及電纜是否有損壞;
當(dāng)輸入更長(zhǎng)的命令脈沖時(shí),電機(jī)偏差計(jì)數(shù)器出現(xiàn)溢出錯(cuò)誤。
失效分析:
-增益設(shè)置太大,再次手動(dòng)調(diào)整增益設(shè)置或使用自動(dòng)調(diào)整增益設(shè)置功能;
-延長(zhǎng)加速/減速時(shí)間;
-負(fù)載太重,有必要選擇更大容量的另一臺(tái)電機(jī)或減少負(fù)載,安裝減速器或其他驅(qū)動(dòng)機(jī)構(gòu),以提高負(fù)載能力。
運(yùn)行期間電機(jī)偏差計(jì)數(shù)器發(fā)生溢出錯(cuò)誤。
失效分析:
-增加偏差計(jì)數(shù)器的超限水平設(shè)定值;
-降低轉(zhuǎn)速;
-延長(zhǎng)加速/減速時(shí)間;
-負(fù)載太重,有必要選擇更大容量的另一臺(tái)電機(jī)或減少負(fù)載,安裝減速器或其他驅(qū)動(dòng)機(jī)構(gòu),以提高負(fù)載能力。
2. How to solve the problem that overrun errors occur in motor deviation counter when servo motor rotates at high speed?
Overrun errors occur in motor deviation counter when servo motor rotates at high speed.
Countermeasure:
Check if wirings of motor power cable and encoder cable match correctly and if there is any damage in cables.
Overrun errors occur in motor deviation counter when much longer command pulse is input.
Countermeasure:
-Gain setting is too large. Manually adjust gain setting again or use automatic adjustment gain setting function.
-Prolong the acceleration/deceleration time.
-The load is too heavy. It is necessary to choose another motor with larger capacity or reduce the load, install speed reducer or other drive mechanism, so as to improve load capacity.
Overrun errors occur in motor deviation counter during operation.
Countermeasure:
-Increase the overrun level set value of deviation counter.
-Reduce the rotation speed.
-Prolong the acceleration/deceleration time.
-The load is too heavy. It is necessary to choose another motor with larger capacity or reduce the load, install speed reducer or other drive mechanism, so as to improve load capacity.
SANYO DENKI無(wú)刷伺服電機(jī)P5系列P50B08100
3.如何解決伺服電機(jī)在無(wú)負(fù)載情況下,運(yùn)行時(shí)報(bào)告過(guò)載的問(wèn)題?
如果在伺服運(yùn)行信號(hào)存取且沒(méi)有脈沖時(shí)發(fā)生該情況:
-檢查伺服電機(jī)電源電纜的接線是否接觸不良或電纜是否有損壞;
-對(duì)于帶制動(dòng)器的伺服電機(jī),請(qǐng)始終打開(kāi)制動(dòng)器;
-速度電路增益是否設(shè)置太大;
-速度電路的積分時(shí)間常數(shù)是否設(shè)置太大。
如果條件只發(fā)生在操作過(guò)程中:
-位置電路增益是否設(shè)置太大;
-定位完成幅度是否設(shè)置太小;
-檢查伺服電機(jī)軸沒(méi)有堵轉(zhuǎn)失速并再次調(diào)整機(jī)械系統(tǒng)。
3. How to solve the problem that overload is reported when servo motor runs without any load?
If the condition occurs when servo run signal is access and there is no pulse:
<span style="margin: 0px; padding: 0px;